Description: System hangs during warm reboot at Critical Memory Initialization 


Software: Error for PowerEdge T130, R230, R330 and T330 serversPowerEdge T130, R230, R330 and T330 servers may report a Critical Error during scheduled warm reboots


Solution:



Critical: Memory Error - An error was detected during memory initialization.

Figure 1: The Critical Memory Error message


The Hardware System Event Logs in the iDRAC/BMC Controller will log an error (Figure 2 [English-only]):

Memory is detected, but is not configurable.

Figure 2: The System Event Log


The LifeCycle Controller Log will record an error (Figure 3 [English-only]):

PST0129 - Memory is detected, but is not configurable.

Figure 3: The LifeCycle Controller log


Chassis with an LCD Display will scroll an error (Figure 4 [English-only])::

PST0129 Memory is detected, but is not configurable. Check memory devices.

Figure 4: LCD display error

BIOS 1.4.5 introduced new Intel Memory Reference Code (MRC) that contains a critical memory initialization fix. Please update to BIOS release 1.4.5 or newer to resolve this issue.

BIOS 2.0.8 that will introduce an additional changes to the System Event Log (SEL) messaging to aid in isolation for any systems that continue to encounter "Memory Detected, but Not Configurable" messages. BIOS 2.0.8 will introduce robust System Event Log (SEL) messaging to help isolate failure point:
  • "No memory is detected" - logged event when no memory is detected
  • "Memory is detected, but is not configurable" - logged event for memory initialization error.
  • "BIOS POST memory test failed" - logged event for memory test error
  • "Incorrect memory configuration" - logged event for unsupported DIMM, Non-ECC DIMM and mixed DIMM

How to download the latest BIOS:

Dell Server PowerEdge R330/R230/T330/T130 BIOS or latest available

Fixes & Enhancements

Fixes

  • -System may stop responding at "Loading BIOS Drivers" bar after the system is turned on.

Enhancements

  • Updated the Intel processor and Memory Reference Codes to production version 4.1.0.1 (or newer)
  • Updated the microcode of the following Intel processors to version 0x48 (or newer):
    • Intel Xeon Processor E3-1200 v6 Product Family
    • Intel Core Processor i3-7000 Product Family
    • Intel Pentium Processor G4600 Product Family
    • Intel Celeron Processor G3930 Product Family
  • Updated the microcode of the following Intel processors to version 0xA0:
    • Intel Xeon Processor E3-1200 v5 Product Family
    • Intel Core Processor i3-6000 Product Family
    • Intel Pentium Processor G4400 or G4500 Product Family
    • Intel Celeron Processor G3900 Product Family
  • Updated the Intel Server Platform Services (SPS) and Manageability Engine (ME) firmware to production release SPS_E3_04.01.03.21 (or newer).
  • Added support for the system running with 2400MHz Dual Inline Memory Modules (DIMMs).
  • Added support for displaying video from the external graphic card.
  • Enhanced reliability support for the system memory test.